Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.020
Filtrar
1.
Microsyst Nanoeng ; 10: 58, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38725436

RESUMO

This work presents a single-structure 3-axis Lorentz force magnetometer (LFM) based on an AlN-on-Si MEMS resonator. The operation of the proposed LFM relies on the flexible manipulation of applied excitation currents in different directions and frequencies, enabling the effective actuation of two mechanical vibration modes in a single device for magnetic field measurements in three axes. Specifically, the excited out-of-plane drum-like mode at 277 kHz is used for measuring the x- and y-axis magnetic fields, while the in-plane square-extensional mode at 5.4 MHz is used for measuring the z-axis magnetic field. The different configurations of applied excitation currents ensure good cross-interference immunity among the three axes. Compared to conventional capacitive LFMs, the proposed piezoelectric LFM utilizes strong electromechanical coupling from the AlN layer, which allows it to operate at ambient pressure with a high sensitivity. To understand and analyze the measured results, a novel equivalent circuit model for the proposed LFM is also reported in this work, which serves to separate the effect of Lorentz force from the unwanted capacitive feedthrough. The demonstrated 3-axis LFM exhibits measured magnetic responsivities of 1.74 ppm/mT, 1.83 ppm/mT and 6.75 ppm/mT in the x-, y- and z-axes, respectively, which are comparable to their capacitive counterparts.

2.
Forensic Sci Int ; 359: 112001, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38714107

RESUMO

BACKGROUND: Cardiac implantable electronic devices (CIED) are a heterogeneous group of medical devices with increasingly sophisticated diagnostic capabilities, which could be exploited in forensic investigations. However, current guidelines are lacking clear recommendations on the topic. The first aim of this systematic review is to provide an updated assessment of the role of postmortem CIED interrogation, and to give practical recommendations, which can be used in daily practice. Secondly, the authors aim to determine the rates of postmortem CIED interrogation and autopsy investigations, the type of final rhythm detected close to death (with a focus on the significance of documented arrhythmias), as well as the role of postmortem CIED interrogation in the determination of final cause/time of death, and any potentially fatal device malfunctions. METHODS: A systematic search in MEDLINE and Scopus aiming to identify reports concerning postmortem human CIED interrogation was performed, including a systematic screening of reference lists. Case reports, letters to the editors, commentaries, review articles or guidelines were excluded, along with studies related to cardiac devices other than CIED. All data were pooled and analyzed using fixed-effects meta-analysis models, and the I2 statistic was used to assess heterogeneity. RESULTS: A total of 25 articles were included in the systematic review, enrolling 3194 decedent CIED carriers. Ten studies (40%) had a 100% autopsy rate, whereas in further 6 studies autopsy findings were variably reported; CIED interrogation was available from 22 studies (88%), and it was never performed prior to autopsy. The overall rate of successful postmortem CIED interrogation was 89%, with high heterogeneity among studies, mainly due to device deactivation/battery discharge. Twenty-four percent of CIED carriers experienced sudden cardiac death (SCD), whereas non-sudden cardiac and non-cardiac death (NSCD, NCD) were reported in 37% and 30% of decedents, respectively. Ventricular tachyarrhythmias were recorded in 34% of overall successfully interrogated CIED, and in 62% of decedents who experienced a SCD; of all ventricular tachyarrhythmias recorded, 40% was found in NSCD or NCD. A clear interpretation of the etiological role of recorded arrhythmias in the causation of death required integration with autopsy findings. Overall, potentially fatal device malfunctions were detected in 12% of cases. CONCLUSIONS: Postmortem CIED interrogation is a valuable tool for the determination of the cause of death, and may complement autopsy. Forensic pathologists need to know the potential utility, pitfalls, and limitations of this diagnostic examination to make this tool as much reliable as possible.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Marca-Passo Artificial/efeitos adversos , Arritmias Cardíacas , Falha de Equipamento
3.
ESC Heart Fail ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38712903

RESUMO

AIMS: Clinical pathways have been shown to improve outcomes in patients with heart failure (HF). Although patients with HF often have a cardiac implantable electronic device, few studies have reported the utility of device-derived risk scores to augment and organize care. TriageHF Plus is a device-based HF clinical pathway (DHFP) that uses remote monitoring alerts to trigger structured telephone assessment for HF stability and optimization. We aimed to evaluate the impact of TriageHF Plus on hospitalizations and describe the associated workforce burden. METHODS AND RESULTS: TriageHF Plus was a multi-site, prospective study that compared outcomes for patients recruited between April 2019 and February 2021. All alert-triggered assessments were analysed to determine the appropriateness of the alert and the workload burden. A negative-binomial regression with inverse probability treatment weighting using a time-matched usual care cohort was applied to estimate the effect of TriageHF Plus on non-elective hospitalizations. A post hoc pre-COVID-19 sensitivity analysis was also performed. The TriageHF Plus cohort (n = 443) had a mean age of 68.8 ± 11.2 years, 77% male (usual care cohort: n = 315, mean age of 66.2 ± 14.5 years, 65% male). In the TriageHF Plus cohort, an acute medical issue was identified following an alert in 79/182 (43%) cases. Fifty assessments indicated acute HF, requiring clinical action in 44 cases. At 30 day follow-up, 39/66 (59%) of initially symptomatic patients reported improvement, and 20 (19%) initially asymptomatic patients had developed new symptoms. On average, each assessment took 10 min. The TriageHF Plus group had a 58% lower rate of hospitalizations across full follow-up [incidence relative ratio: 0.42, 95% confidence interval (CI): 0.23-0.76, P = 0.004]. Across the pre-COVID-19 window, hospitalizations were 31% lower (0.69, 95% CI: 0.46-1.04, P = 0.077). CONCLUSIONS: These data represent the largest real-world evaluation of a DHFP based on multi-parametric risk stratification. The TriageHF Plus clinical pathway was associated with an improvement in HF symptoms and reduced all-cause hospitalizations.

4.
JMIR Mhealth Uhealth ; 12: e51201, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38669071

RESUMO

BACKGROUND: Numerous smartphone apps are targeting physical activity (PA) and healthy eating (HE), but empirical evidence on their effectiveness for the initialization and maintenance of behavior change, especially in children and adolescents, is still limited. Social settings influence individual behavior; therefore, core settings such as the family need to be considered when designing mobile health (mHealth) apps. OBJECTIVE: The purpose of this study was to evaluate the effectiveness of a theory- and evidence-based mHealth intervention (called SMARTFAMILY [SF]) targeting PA and HE in a collective family-based setting. METHODS: A smartphone app based on behavior change theories and techniques was developed, implemented, and evaluated with a cluster randomized controlled trial in a collective family setting. Baseline (t0) and postintervention (t1) measurements included PA (self-reported and accelerometry) and HE measurements (self-reported fruit and vegetable intake) as primary outcomes. Secondary outcomes (self-reported) were intrinsic motivation, behavior-specific self-efficacy, and the family health climate. Between t0 and t1, families of the intervention group (IG) used the SF app individually and collaboratively for 3 consecutive weeks, whereas families in the control group (CG) received no treatment. Four weeks following t1, a follow-up assessment (t2) was completed by participants, consisting of all questionnaire items to assess the stability of the intervention effects. Multilevel analyses were implemented in R (R Foundation for Statistical Computing) to acknowledge the hierarchical structure of persons (level 1) clustered in families (level 2). RESULTS: Overall, 48 families (CG: n=22, 46%, with 68 participants and IG: n=26, 54%, with 88 participants) were recruited for the study. Two families (CG: n=1, 2%, with 4 participants and IG: n=1, 2%, with 4 participants) chose to drop out of the study owing to personal reasons before t0. Overall, no evidence for meaningful and statistically significant increases in PA and HE levels of the intervention were observed in our physically active study participants (all P>.30). CONCLUSIONS: Despite incorporating behavior change techniques rooted in family life and psychological theories, the SF intervention did not yield significant increases in PA and HE levels among the participants. The results of the study were mainly limited by the physically active participants and the large age range of children and adolescents. Enhancing intervention effectiveness may involve incorporating health literacy, just-in-time adaptive interventions, and more advanced features in future app development. Further research is needed to better understand intervention engagement and tailor mHealth interventions to individuals for enhanced effectiveness in primary prevention efforts. TRIAL REGISTRATION: German Clinical Trials Register DRKS00010415; https://drks.de/search/en/trial/DRKS00010415. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.2196/20534.


Assuntos
Dieta Saudável , Exercício Físico , Promoção da Saúde , Aplicativos Móveis , Telemedicina , Humanos , Masculino , Feminino , Exercício Físico/psicologia , Exercício Físico/fisiologia , Dieta Saudável/métodos , Dieta Saudável/psicologia , Telemedicina/métodos , Telemedicina/normas , Telemedicina/instrumentação , Adolescente , Criança , Aplicativos Móveis/normas , Aplicativos Móveis/estatística & dados numéricos , Promoção da Saúde/métodos , Promoção da Saúde/normas , Adulto , Família/psicologia , Pessoa de Meia-Idade
6.
Int J Stroke ; : 17474930241253482, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38676601

RESUMO

BACKGROUND: Paroxysmal atrial fibrillation (PAF) is strongly associated with ischemic stroke. Continuous cardiac implantable electronic devices (CIEDs) can assess PAF episodes over prolonged periods. Studies that attempted to find a temporal association between PAF and ischemic stroke were inconclusive. Thus, we performed a systematic review and meta-analysis to assess this relationship. AIMS: To assess the temporal association between AF episodes and stroke within 30 days of the arrhythmic episode. The secondary outcome is a temporal association within a 90-day period. SUMMARY OF REVIEW: A total of 2804 studies that discussed the temporal relationship between PAF and ischemic stroke were screened, and 7 studies were included in the meta-analysis. Amongst the 4041 patients included in these studies, there were 138 patients with device detected PAF episodes and stroke. Four studies used a 30-day window for temporality and the pooled OR showed a significant association (OR 4.11 [95% CI 1.03-16.40]). The 3 studies reporting on AF and stroke within a 90 day window did not find a significant temporal relationship (OR of 0.43 [95% CI 0.13-1.41]). Finally, the pooled result of those 7 studies did not show a significant association (OR 1.51 [95% CI 0.44 - 5.17]). CONCLUSIONS: This meta-analysis supports a temporal relationship between PAF and ischemic stroke within a 30-day window. Establishing this relationship is important for individualized risk prediction and targeted anticoagulation treatment.

7.
J Patient Rep Outcomes ; 8(1): 42, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38592366

RESUMO

OBJECTIVE: This study compares clinical pain outcomes between patients in a pain treatment program that received a Fitbit, to patients that did not. We also explored: (1) cognitive, emotional, and psychological factors that may have impacted the decision to opt in to receiving a Fitbit; and (2) whether the choice to receive a Fitbit impacted changes in cognitive, emotional, and psychological factors following treatment. METHODS: Among 58 patients in a multidisciplinary pain treatment program at a Veterans Affairs Healthcare System hospital, 31 patients opted to receive a Fitbit as adjunct treatment, while 27 did not. This study utilized patient-reported and practitioner-collected data from the pain treatment program. RESULTS: Compared to the non-Fitbit group, the Fitbit group displayed a significant decrease in average pain intensity, however showed no correlation between Fitbit activity and average pain intensity. Additionally, treatment satisfaction was the only predictor of treatment group, when modeling pre- and post-treatment outcomes changes. CONCLUSION: The implementation of a Fitbit may lead to improved pain intensity. Initial evidence suggests that opting to receive a Fitbit during a pain treatment program indicates treatment engagement leading to greater treatment satisfaction. Future work is needed to verify and expand upon this potential mechanism.


Assuntos
Motivação , Veteranos , Humanos , Manejo da Dor , Resultado do Tratamento , Dor
8.
Heart Rhythm O2 ; 5(3): 158-167, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38560372

RESUMO

Background: Cardiac implantable electronic devices (CIEDs), such as permanent pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy devices, alleviate morbidity and mortality in various diseases. There is a paucity of real-world data on CIED complications and trends. Objectives: We sought to describe trends in noninfectious CIED complications over the past 3 decades in Olmsted County. Methods: The Rochester Epidemiology Project is a medical records linkage system comprising records of over 500,000 residents of Olmsted County from 1966 to present. CIED implantations between 1988 and 2018 were determined. Trends in noninfectious complications within 30 days of implantation were analyzed. Results: A total of 157 (6.2%) of 2536 patients who received CIED experienced device complications. A total of 2.7% of the implants had major complications requiring intervention. Lead dislodgement was the most common (2.8%), followed by hematoma (1.7%). Complications went up from 1988 to 2005, and then showed a downtrend until 2018, driven by a decline in hematomas in the last decade (P < .01). Those with complications were more likely to have prosthetic valves. Obesity appeared to have a protective effect in a multivariate regression model. The mean Charlson comorbidity index has trended up over the 30 years. Conclusion: Our study describes a real-world trend of CIED complications over 3 decades. Lead dislodgements and hematomas were the most common complications. Complications have declined over the last decade due to safer practices and a better understanding of anticoagulant management.

9.
Front Microbiol ; 15: 1361626, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38559357

RESUMO

Introduction: One of the biggest obstacles in diagnosing Implant-Associated Infections is the lack of infection criteria and standardized diagnostic methods. These infections present a wide range of symptoms, and their diagnosis can be hampered by the formation of microbial biofilms on the surface of implants. This study aimed to provide insight into the performance of sonication in the diagnosis of infections associated with Cardiac Implantable Electronic Devices, to help define a consensus on the algorithm for the microbial diagnosis of these infections. Methods: We carried out a systematic review with meta-analysis. The PRISMA methodology guidelines were followed, and an advanced search was carried out in PubMed and Web of Science, which enabled 8 articles to be included in the review, in which a meta-analysis was also carried out. QUADAS-2 was used to assess the risk of bias and effect measures were calculated to assess publication bias. Results: The overall sensitivity of the method was 0.823 (95% CI: 0.682-0.910) and the specificity was 0.632 (95% CI: 0.506-0.743). Discussion: These results suggest that sonication may offer advantages in diagnosing these infections. However, it is essential to approach these findings carefully and take into account the recommendations provided in the EHRA 2019 guidelines. This study highlights the importance of more effective diagnostic approaches for implantable medical device-associated infections to improve the quality of treatment and minimize the risks associated with these challenging medical conditions.

11.
Stud Health Technol Inform ; 313: 221-227, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38682534

RESUMO

BACKGROUND: This study focuses on the development of a neural network model to predict perceived sleep quality using data from wearable devices. We collected various physiological metrics from 18 participants over four weeks, including heart rate, physical activity, and both device-measured and self-reported sleep quality. OBJECTIVES: The primary objective was to correlate wearable device data with subjective sleep quality perceptions. METHODS: Our approach used data processing, feature engineering, and optimizing a Multi-Layer Perceptron classifier. RESULTS: Despite comprehensive data analysis and model experimentation, the predictive accuracy for perceived sleep quality was moderate (59%), highlighting the complexities in accurately quantifying subjective sleep experiences through wearable data. Applying a tolerance of 1 grade (on a scale from 1-5), increased accuracy to 92%. DISCUSSION: More in-depth analysis is required to fully comprehend how wearables and artificial intelligence might assist in understanding sleep behavior.


Assuntos
Redes Neurais de Computação , Dispositivos Eletrônicos Vestíveis , Humanos , Masculino , Qualidade do Sono , Feminino , Adulto , Frequência Cardíaca/fisiologia , Autorrelato
12.
Micromachines (Basel) ; 15(4)2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38675242

RESUMO

The problem that the thermal safety of flexible electronic devices is difficult to evaluate in real time is addressed in this study by establishing a BP neural network (GA-BPNN) temperature prediction model based on genetic algorithm optimisation. The model uses a BP neural network to fit the functional relationship between the input condition and the steady-state temperature of the equipment and uses a genetic algorithm to optimise the parameter initialisation problem of the BP neural network. To overcome the challenge of the high cost of obtaining experimental data, finite element analysis software is used to simulate the temperature results of the equipment under different working conditions. The prediction variance of the GA-BPNN model does not exceed 0.57 °C and has good robustness, as the model is trained according to the simulation data. The study conducted thermal validation experiments on the temperature prediction model for this flexible electronic device. The device reached steady state after 1200 s of operation at rated power. The error between the predicted and experimental results was less than 0.9 °C, verifying the validity of the model's predictions. Compared with traditional thermal simulation and experimental methods, this model can quickly predict the temperature with a certain accuracy and has outstanding advantages in computational efficiency and integrated application of hardware and software.

13.
Front Cardiovasc Med ; 11: 1364940, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38586175

RESUMO

Background: A novel non-contact system for remote parameter testing and reprogramming offers an alternative method for assessing device parameters during cardiac implantable electronic devices (CIEDs) implantation without the need for physical contact with the manufacturer's clinical service technician. The safety and feasibility of using this system in CIEDs implantation procedures remains to be determined. Objective: Evaluate the safety and feasibility of remote parameter testing in CIEDs implantation procedures. Methods: A single center, randomized, open-label, non-inferiority trial (ChiCTR2200057587) was conducted to compare the two approaches for interrogating CIEDs during implantation procedures: routine interrogation performed by on-site technicians or remote interrogation performed by technicians using the 5G-Cloud Technology Platform. Patients aged ≥18 years and elected to receive CIEDs were eligible for inclusion. The primary endpoint was the completion rate of the parameter test. Safety and efficiency were evaluated in all randomly assigned participants. Results: A total of 480 patients were finally enrolled and were randomly assigned to routine group (n = 240) or remote group (n = 240). The primary endpoint was achieved by 100% in both groups (P = 0.0060 for noninferiority). The parameters of sensing, threshold, and impedance regarding the right atrium, right ventricle, and left ventricle had no statistical significance between the two groups (P > 0.05). Procedure time, parameter testing time, and both duration and dose of x-ray irradiation were not significantly different between the two groups (P > 0.05). Shut-open door frequency was significantly higher in the routine group than the remote group [6.00 (4.00, 8.00) vs. 0, P < 0.0001]. Notably, no clinical or technical complications were observed in the remote group. Conclusions: Remote parameter testing is safe and feasible across various devices implantation procedures. The utilization of remote parameter testing and reprogramming could represent an innovative approach to improve healthcare accessibility and unlock the full potential of secondary centers in managing CIEDs. The Registration Identification: ChiCTR2200057587.

14.
Physiol Behav ; 280: 114562, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38641187

RESUMO

Screen time (ST) on digital devices has increased in recent decades due to digital development. Furthermore, constant engagement with digital devices alters sleep patterns, leading to nocturnal eating behaviour among users. These phenomena are therefore of great concern, as digital device addiction and night eating are associated with unhealthy food intake, increasing the metabolic syndrome (MetS) risks. The purpose of this review was to examine the evidence of the influence of ST and night eating behaviour (NEB) on dietary intake and its association with MetS based on previous literature. Prolonged ST and NEB have an association with excessive intake of energy from overconsumption of high-sugar and high-fat foods. However, the relationship between digital content and its influence on food intake is inconsistent. A higher MetS risk was found in individuals with longer ST due to a sedentary lifestyle, while positive energy balance and a shift in circadian rhythm contributed to night eaters. ST and NEB presented with a significant influence on food intake in adults. Additionally, unhealthy food intake due to excessive consumption of empty-calorie foods such as sweet and fatty foods due to addiction to electronic devices and eating at night has a detrimental effect on metabolic function. Therefore, improving food intake by reducing ST and night binges is essential to reduce the risk of MetS.


Assuntos
Ingestão de Alimentos , Comportamento Alimentar , Síndrome Metabólica , Tempo de Tela , Humanos , Síndrome Metabólica/etiologia , Comportamento Alimentar/fisiologia , Ingestão de Alimentos/fisiologia
15.
Pacing Clin Electrophysiol ; 47(5): 626-634, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38488756

RESUMO

BACKGROUND: Long-term outcomes of sterile lead management strategies of lead abandonment (LA) or transvenous lead extraction (TLE) remain unclear. METHODS: We performed a retrospective study of a population residing in southeastern Minnesota with follow-up at the Mayo Clinic and its health systems. Patients who underwent LA or TLE of sterile leads from January 1, 2000, to January 1, 2011, and had follow-up for at least 10 years or until their death were included. RESULTS: A total of 172 patients were included in the study with 153 patients who underwent LA and 19 who underwent TLE for sterile leads. Indications for subsequent lead extraction arose in 9.1% (n = 14) of patients with initial LA and 5.3% (n = 1) in patients with initial TLE, after an average of 7 years. Moreover, 28.6% of patients in the LA cohort who required subsequent extraction did not proceed with the extraction, and among those who proceeded, 60% had clinical success and 40% had a clinical failure. Subsequent device upgrades or revisions were performed in 18.3% of patients in the LA group and 31.6% in the TLE group, with no significant differences in procedural challenges (5.2% vs. 5.3%). There was no difference in 10-year survival probability among the LA group and the TLE group (p = .64). CONCLUSION: An initial lead abandonment strategy was associated with more complicated subsequent extraction procedures compared to patients with an initial transvenous lead extraction strategy. However, there was no difference in 10-year survival probability between both lead management approaches.


Assuntos
Remoção de Dispositivo , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Minnesota/epidemiologia , Desfibriladores Implantáveis , Marca-Passo Artificial , Resultado do Tratamento , Pessoa de Meia-Idade , Eletrodos Implantados
16.
J Cardiovasc Electrophysiol ; 35(5): 1050-1054, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501328

RESUMO

INTRODUCTION: Tricuspid regurgitation is associated with significant morbidity and mortality, and occurs at a higher rate in patients with cardiovascular implantable electronic devices. Percutaneous strategies for managing tricuspid regurgitation are evolving, including the development of bicaval valve implantation which has been successfully used in patients with pacing leads. METHODS AND RESULTS: We present the first documented case of lead failure following TricValve® implantation, a dedicated self-expanding system for bicaval valve implantation, and the first successful lead revision procedure in this setting. CONCLUSION: The case illustrates important considerations in undertaking percutaneous intervention in patients with cardiovascular implantable electronic devices, and their ongoing management.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Masculino , Idoso , Resultado do Tratamento , Reoperação , Desenho de Prótese , Remoção de Dispositivo , Feminino , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos
17.
Pediatr Radiol ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38488925

RESUMO

Magnetic resonance imaging (MRI) is now an indispensable diagnostic tool in medicine due to its outstanding contrast resolution and absence of radiation exposure, enabling detailed tissue characterization and three-dimensional anatomical representation. This is especially important when evaluating individuals with congenital heart disease (CHD) who frequently require cardiac implantable electrical devices (CIEDs). While MRI safety issues have previously limited its use in patients with CIEDs, new advances have called these limitations into question. However, difficulties persist in the pediatric population due to the continued lack of specific safety data both related to imaging young children and the specific CIED devices they often require. This paper discusses MRI safety considerations related to imaging patients with CIEDs, investigates pediatric-specific problems, and describes thorough methods for safe MRI access, highlighting the significance of specialized institutional guidelines.

19.
Cureus ; 16(3): e55982, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38476505

RESUMO

Video head impulse test (vHIT) artifacts are defined as spurious elements or disturbances in the recorded data that deviate from the true vestibulo-ocular reflex response. These artifacts can arise from various sources, encompassing technological limitations, patient-specific factors, or environmental influences, introducing inaccuracies in vHIT outcomes. The absence of standardized criteria for artifact identification leads to methodological heterogeneity. This narrative review aims to comprehensively examine the challenges posed by artifacts in the vHIT. By surveying existing literature, the review seeks to elucidate the multifaceted nature of artifacts arising from technological, patient-related, evaluator-related, and environmental factors.

20.
Korean Circ J ; 54(3): 140-153, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38506104

RESUMO

BACKGROUND AND OBJECTIVES: Although a single-lead electrocardiogram (ECG) patch may provide advantages for detecting arrhythmias in outpatient settings owing to user convenience, its comparative effectiveness for real-time telemonitoring in inpatient settings remains unclear. We aimed to compare a novel telemonitoring system using a single-lead ECG patch with a conventional telemonitoring system in an inpatient setting. METHODS: This was a single-center, prospective cohort study. Patients admitted to the cardiology unit for arrhythmia treatment who required a wireless ECG telemonitoring system were enrolled. A single-lead ECG patch and conventional telemetry were applied simultaneously in hospitalized patients for over 24 hours for real-time telemonitoring. The basic ECG parameters, arrhythmia episodes, and signal loss or noise were compared between the 2 systems. RESULTS: Eighty participants (mean age 62±10 years, 76.3% male) were enrolled. The three most common indications for ECG telemonitoring were atrial fibrillation (66.3%), sick sinus syndrome (12.5%), and atrioventricular block (10.0%). The intra-class correlation coefficients for detecting the number of total beats, atrial and ventricular premature complexes, maximal, average, and minimal heart rates, and pauses were all over 0.9 with p values for reliability <0.001. Compared to a conventional system, a novel system demonstrated significantly lower signal noise (median 0.3% [0.1-1.6%] vs. 2.4% [1.4-3.7%], p<0.001) and fewer episodes of signal loss (median 22 [2-53] vs. 64 [22-112] episodes, p=0.002). CONCLUSIONS: The novel telemonitoring system using a single-lead ECG patch offers performance comparable to that of a conventional system while significantly reducing signal loss and noise. TRIAL REGISTRATION: Clinical Research Information Service Identifier: KCT0008176.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...